LD-3010 Series
1a
Rough-Ins for OmniDeck with SL-TO1 Oval Undermount Bowl
22"
(559mm)
Code
A
⁄
" Anchors with a Minimum Pull-Out Force of 1,000 lbs. (reinforce wall at anchor points)
3
8
B
#10 Wall Anchors and Screws
H, C
½" Nominal Copper Tubing for Hot/Cold Supplies, Stub-Out 2" (51mm) From Finished Wall
D
AC Option Only: 110v GFI Protected Electrical Outlet
E
1½" NPT Drain, Stub-Out 2" (51mm) From Wall
F
TMA Option Only: #10 Wall Anchors and Screws
G
8" (203mm)
4
Typical OmniDeck rough-ins for single SL-TO1 oval bowl are shown. Other multiple-bowl rough-ins
are similar.
For juvenile height mounting, the mounting height dimension from the deck surface to the finished
floor is 31" (787mm) maximum. Adjust all other mounting locations accordingly.
Variable
2" (51mm)
1½" (38mm)
A
B
G
B
D
G
B
Trap
(83mm)
19"
Cover
(483mm)
20¼"
(514mm)
Finished Floor
7/16/2013
Variable
2" (51mm)
B
F
F
H
C
B
E
B
3¼"
10¹⁄₈"
(257mm)
(610mm)
Description
A
9"
(229mm)
34" (864mm)
deck surface
maximum
ADA
27¾"
(705mm)
22"
(559mm)
24"
Bradley • 215-1219 Rev. M; ECN 13-11-002A
Installation
Qty.
2 per bracket
6
2
1
1
2
2