6.2.2.2 Power supply cable version from
100Vac to 240Vac
The device is Class I. Connection of the
yellow-green cable to the safety ground
is therefore necessary to ensure electrical
safety.
The illuminator is provided with a 2m power cable.
Power cables (blue, brown, yellow/green): Connect
the brown cable to the phase, the blue one to the
neutral and the yellow-green one to the safety
ground.
For maximum lengths and recommended cable
sections, refer to the relative chapter (6.2.3 Cable
technical specifications, page 9).

6.2.2.3 Control cable

The product is equipped with a control cable to
manage one input contact and one output contact.
COLORS AND FEATURES OF THE CONTROL CABLE
Cable color
Function
Red
Input for activation by means of external dry
contact
Green
Input for activation by means of external dry
contact
White
Dry contact output (Follow)
Black
Dry contact output (Follow)
Tab. 1
8
Input contact: It allows a remote activation of the
illuminator by means of a clean contact placed
between the red and green conductors. For proper
operation, make sure that the twilight sensor is
disabled (6.2.4.2 Disabling the twilight sensor, page 
10). The input contact status is the following:
• Open contact input (insulated red and green
poles): Illuminator on.
• Contact closed input (red and green poles in short-
circuit): Illuminator off.
Avoid to use the same external contact
to switch-on or switch-off 2 or more
illuminators.
Input contact
Illuminator 01
Input contact
Illuminator 01
Fig. 10
Output contact (Follow): The Follow output has
a clean contact in the white and black poles. The
Follow contact can be used to turn on or off other
illuminators simultaneously in the system or to
verify the camera day/night status. Regardless the
illuminator is activated through the input contact or
the twilight sensor, the output contact status (Follow)
is the following:
• Open contact output (insulated white and black
poles): Illuminator on.
• Contact closed output (white and black poles in
short-circuit): Illuminator off.