Fasten the bracket as shown in the figure. Drive the
wall screws in tight.
Fig. 5
Fasten the illuminator, complete with its bracket,
using the screw, the nut and the washer supplied.
Fig. 6
Set the illuminator's vertical and horizontal
inclination by adjusting the two fastening screws.
Fig. 7
Check the resulting illumination range on the screen.
Tighten all the screws.
MNVCIRN_1420_EN
6.2.2 Description of connection cables
Control cable
Fig. 8 12Vdc, 24Vdc and 24Vac version.
Control cable
Fig. 9 From 100Vac to 240Vac version.
6.2.2.1 Power supply cable version 12Vdc,
24Vdc, and 24Vac
The device is Class III. Provide power
supply using a safety transformer or a SELV
continuous current power supply.
The illuminator is provided with a 2m power cable.
Power cables (blue, brown): Connect the two
poles to the supply (24Vac, 50/60Hz or 12-24Vdc). In
case of continuous current power supply, polarity is
irrelevant.
For maximum lengths and recommended cable
sections, refer to the relative chapter (6.2.3 Cable
technical specifications, page 9).
Power supply
Power supply
7