Roger Technology BH30 Serie Instructions Et Avertissements Pour L'installateur page 21

Automatisme pour portails coulissants
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33
12
Magnetic limit switches connections
The gate open and gate closed limit switch outputs are OPEN COLLECTOR signals.
13
Start-up
• Check that the manual release device functions correctly.
• The installer is required to draw up and preserve the technical file of the system for at least 10 years, which must contain the wiring
diagram, the drawing and the photo of the system, the risk analysis and the solutions adopted, the manufacturer's declaration of conformity
for all connected devices, the instructions manual of each device and / or accessory and the system's maintenance plan.
• Apply a plate indicating the automation system data on the motorised door or gate, the name of the person in charge of the start-up, the
serial number and the year of construction, as well as the CE mark.
• Apply a plate and / or label with the indications for the operations required to manually unlock the system.
• Draw up and provide the end user with the declaration of conformity, instructions and warnings for use and the maintenance plan.
• Make sure that the end user has understood the correct automatic, manual or emergency operation of the system.
• Inform the end user about the dangers and risks that may be present.
14
Ordinary maintenance schedule
Perform the following operations and checks every 6 months, depending on the intensity of use of the automated system.
Disconnect the mains power and the batteries (if any) and unlock the gear motor (SEE THE USER MANUAL):
• Perform a visual check to determine if the gate, the fastening brackets and the existing structure have the required mechanical robustness and that they
are in good state.
• Check the gate-gear motor alignment and the distance (1-2 mm) between the pinion neck and the ridge of the rack.
• Clean the guide rails of the wheels, the rack and the pinion of the gear motor and lightly lubricate the rack and the pinion of the gear motor.
• Manually check that the gate slides smoothly and without impediment.
Reconnect the mains power and the batteries (if any) and lock the gear motor (SEE THE USER MANUAL):
• Check if the limit switches operate correctly.
• Check the force adjustments.
• Check that the safety devices and all control functions operate correctly.
15
Additional information and contact details
ROGER TECHNOLOGY is the exclusive proprietor holder of all rights regarding this publication.
ROGER TECHNOLOGY reserves the right to implement any modifications without prior notification. Copying, scanning or any alterations to this document are
prohibited without express prior authorised from by ROGER TECHNOLOGY.
This instruction manual and the warnings for the installer are given in printed form and included in the box containing the product.
The digital version of this documentation (in PDF format) and all future revisions are available from the reserved area of our website www.rogertechnology.
com/B2B, in the section 'Self Service'.
ROGER TECHNOLOGY CUSTOMER SERVICE:
business hours:
Monday to Friday
08:00 to 12:00 - 13:30 to 17:30
Telephone no:
+39 041 5937023
E-mail:
service@rogertechnology.it
Skype:
service_rogertechnology
24V AC/DC
ROSSO / RED
FCA
MARRONE / BROWN
FCC
BLU / BLUE
COM
NERO / BLACK
24V AC/DC
FCA (OPEN COLLECTOR)
FCC (OPEN COLLECTOR)
COM
21 21