3
Configuration
Caution
The CPV Direct contains electronically sensitive compo
nents. The CPV Direct will be damaged if you touch the
contact surfaces of the plug connectors or if you do not
observe the regulations for handling electrostatically
sensitive components.
Proceed as follows when configuring:
1. Switch off the power supply.
2. Remove the switch module.
3. Set the following with the DIL switches: compatibility,
extension to the CP system, station number, baud rate.
4. Refit the switch module.
5. If the CP system is the first or last slave in a field bus
segment, a terminating resistor must be fitted be
tween the field bus cables (120
Warning
S Make sure that switch−on test pulses are sup
pressed/switched off when you operate the CPV
Direct via a safety I/O module."
S Check the measures required for putting your system
into a safe status in the event of an EMERGENCY
STOP.
Further information can be found in manual P.BE−CP−
DN2−.. .
Festo CPV..−GE−DN2−8 0503b English
Ω
, 0.25 W).
17