Operation
No. Description
Restricted operation
Switch-over of the room control unit operat-
032
ing lock between "Standard" and "Restricted
operation".
External sensor (only Control)
Registration of an external room/floor sensor
or dew point sensor (TPS). The registration
of a room sensor (1) deactivates the internal
sensor. If a floor sensor (2) is used, the min-
imum floor temperature can be set via the
040
Settings menu in the function "External floor
DEU
sensor".
ENG
ENG
FRA
Correction of actual temperature of
external sensor (only Control)
NDL
041
Corrects a deviating measurement of the ac-
tual temperature.
ITA
Inverting the dew point sensor
(Control only)
ESP
Reverses the control direction of the dew
042
point sensor registered with the device.
NO = Normally Open
NC = Normally Closed
Duration of the display illumination
Sets the duration of further illumination of
050
the display after use.
Signalling of switching output
Signalises the control of switching outputs by
090
a flashing heating resp. cooling symbol.
46
A floor sensor (2) can only be used in
the "Heating"( ) voperating mode.
Setting
0 = deactivated
1 = activated
Standard: 0
0 = no external
sensor
1 = room sensor
2 = floor sensor
3 = dew point
sensor (TPS)
Standard: 0
-2 ... +2 °C
Standard: 0 °C
0 = NC
1 = NO
Standard: 0
0 ... 30 sec.
in 5 second incre-
ments
Standard: 15 sec.
0 = deactivated
1 = activated
Standard: 1