TROUBLESHOOTING
PROBLEM
Appliance won't light
Burner will not light using a match
Appliance emits a lot of black smoke
when lit
Sudden drop in gas flow
Flame blow out
Irregular flame pattern or flame does not
come out of the entire length of the burner
CAUSE
Igniter pin and burner are
wet
Igniter battery is
incorrectly inserted.
Igniter pin cracked or
broken
Electrode wire is loose or
disconnected
Electrode wire is shorting
between valve and igniter
pin
No gas flow
Regulator is not fully
connected to the tank
Gas flow is obstructed
Spider webs or insect nest
in the venturi (end of
burner tube)
Burner ports are clogged
Flame is obstructed at
burner ports
Regulator hose is pinched
No gas flow
Excess flow safety valve
has been activated
High or gusting winds
No gas flow
Excess flow safety valve
has been activated
Burner ports are clogged
IF YOU HAVE QUESTIONS OR CONCERNS
PLEASE CALL BOND TOLL FREE #
1-866-771-BOND(2663) OR TO BETTER
EXPEDITE YOUR REQUEST FEEL FREE TO EMAIL US
customerservice@bondmfg.com
OR LOG IN TO OUR WEBSITE UNDER CUSTOMER SERVICE SUPPORT
www.bondmfg.com
BOND MANUFACTURING CO.
1700 West 4th Street, Antioch CA 94509
11
CORRECTIVE ACTION
Wipe dry with a cloth
Check that battery is correctly inserted.
Call customer service for replacement part
Reconnect wire to the igniter box
located inside the table base behind
the igniter button
Call customer service for replacement part
Check if gas cylinder is empty. If yes, replace.
Check LP tank connection.
Check hose for bends or kinks
Clean the venturi
Insert an opened paperclip into each of the burner ports to clean
them. Ensure the appliance is off and all parts are cooled before
attempting to clean the burner ports
Make sure all the gas burner ports are free of any lava rocks or
debris to allow the gas to flow freely.
Check the regulator hose for bends or kinks
Check if gas cylinder is empty. If yes, replace.
Turn the control knob to "OFF", Close the LP tank valve and
disconnect the regulator from the tank. Turn the control knob to
"HIGH". Wait 1 minute. Turner the control knob to "OFF".
Reconnect regulator to LP tank. Open tank valve slowly. Light
appliance as indicated in "To Light" section.
Increase flame to "High"
Check if gas cylinder is empty. If yes, replace.
See "Sudden drop in gas flow" above
See "Burner will not light using a match" above.