One unit has 13 channels for DMX control, so each unit must be assigns 13 channels at least. We may
assign 16 channels for one unit, then DMX address : 16*N+1, N=0, 1, 2, 3....
Example: 1- loop address = 1 / 2-loops addresses = 17 / 3-loop addresses=33 / 4-loop addresses=49
LOOP
ADDRESS
1
1
2
17
3
33
4
49
OPERATION
Sound-Active / Auto mode
The mode allows a single unit to react to the beat of the music in the master mode.
1.
Install the unit in a suitable position (laying or appending)
2.
Set function setting switch to select Sound-Active or AUTO mode
3.
Turn on the unit power, the unit begins reset, then the unit begins working
4.
The unit will react to the low frequencies of music via the internal microphone. Adjust
the audio sensitivity knob on the back of the unit to make the unit more or less sensitive
in Sound-Active mode.
Master/Slave mode
This mode allows you to link many units together without controller
1.
Install the unit in a suitable position (laying or appending)
2.
Choose the unit to function as Master, set dipswitch to select Sound Active or Auto mode.
The other units must be set as Slave and set dipswitch as so.
3.
Use standard XLR microphone cable to link the units together via the XLR connector on the
rear of the units.
4.
Turn on all the units. They begin to reset then they begin working. The slave units will react
the same as the Master unit.
5.
The units will react to the low frequencies of the music via the internal microphone. Adjust the
audio sensitivity knob on the rear of the master unit to make the unit more or less sensitive in
Sound-Active. The panel has LED indicating for Sound-Active
Universal DMX operation
This mode allows you to use universal DMX-512 console to operate
1.
Install the unit in a suitable position (laying or appending)
2.
Use standard XLR microphone cable to link your units together via the XLR connector on the
rear of the units.
3.
Assign DMX address to each unit using dipswitches (see 'DMX Address Quick Reference
Chart)
4.
Turn on all the units, they begin to reset then they begin working
5.
Use DMX console to control your units
BINARY
100000000 #1 (#1 is ON, others are OFF)
100010000 #1+#5 (only #1 and #5 are ON)
100001000 #1+#6 (only #1+#6 are ON)