4.2.3.1 Example of Auto Operating
Mode
8 V
PE. 4
ou. 4
3 V
2 V
10 s 20 s 30 s 40 s 50 s
The best way to program such a
function is to set up a table like the
one opposite:
5. Technical Data
Display
Supply voltage:
Current consumption: 39 mA at 25°C, for a 20 mA output current
Power consumption: max. 1 W,
Test voltage:
Test voltages:
EMC:
Operating temp.:
Storage temp.:
Air humidity:
10
PE. 5
ou. 5
4-digit red 7-segment LED display, height 8 mm
10 ... 30 V DC, electrically isolated
500 V, 50 Hz., 1 min.
EN 61010-1 for contamination level 2 and
overvoltage category 2
Interference emissions EN 55011 Class B
Interference immunity EN61000-6-2
-20 ... +65 °C, without condensation
-25 ... +85 °C, without condensation
90 % at 25 °C, without condensation
Example
PEr
8
ou. 1
0 V
PE. 1
5 s
ou. 2
3 V
PE. 2
5 s
ou. 3
2 V
PE. 3
10 s
ou. 4
3 V
PE. 4
10 s
ou. 5
3 V
PE. 5
10 s
ou. 6
8 V
PE. 6
10 s
ou. 7
8 V
PE. 7
10 s
ou. 8
0 v
PE. 8
5 s
Own values
www.kuebler.com