1 sec
2. The function
page 9
–
SiGnal allows selecting
the setpoint output in volts or mA.
–
time allows selecting
the time in seconds or minutes.
–
Number of PEriods
allows defining the number of refer-
ence points.
–
output 1 allows select-
ing the value of the current or volt-
age for the first reference point.
–
PEriod. 1 allows defin-
ing the first period.
(A maximum of 20 periods may be
programmed) The maximum set-
points ou. X and the times PE. X
result from the setting of PEr.
–
The function cYcle
allows defining the number of cycles
to be carried out.
–
Selecting noCYcle will
start an endless loop.
8
to
to
to
see
Press both keys simultaneously to
switch over to the following parameter.
Within a parameter, select the decade
with the left key and select a value
from 0 ... 9 with the right key.
3. After setting the value of cYcl,
press both keys simultaneously;
the following message is displayed:
4. Use the right key to select YES or
no
⇑
5. If YES is selected, press both
keys simultaneously to end the
programming
⇑
⇑
6. The device is now ready for
operation. Press the right key to
start it and the left key to stop it.
www.kuebler.com