Decimal Point Setting; End Of Programming - Kübler CODIX 520 Mode D'emploi

Masquer les pouces Voir aussi pour CODIX 520:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

c1.Hold the left key pressed and press the right
key to leave the programming operation
c2.Press the right key to switch to
d. Hold the left key pressed and press the right
key to switch to the first parameter.
e. After releasing the the right keys, the display
alternates between the menu title and the cur-
rent menu item setting. After pressing down
any key, only the menu item setting is dis-
played.
f. Pressing the right key, the menu item setting
will be switched to the next value.
If figures are to be input (e.g. when setting the
scaling factor), select first the digit using the
left key, and then set the value using the right
key.
g. Hold the left key pressed and press the right
key to switch to the next menu item.
h. The last menu title "EndPro" allows, when
selecting "Yes", to exit the programming menu
and to take over (store) the new values. If "no"
is selected, the programming routine is repeat-
ed, the latest values set remaining active. They
can now be checked aain or modified.
4. Programming routine
The programmable parameters of the device are
described below, in succession. The device is
fully programmed after one pass of the routine.
The first values stated correspond to the factory
settings
4.1 Polarity of the inputs
2
.
npn: switching to 0 V
pnp: switching to +U B
4.2 Switching on the 30 Hz filter (INP)

4.3 Decimal point setting

4.4 RESET Mode

4.5 End of programming

* where bounce occurs, e.g. with contacts
The filter provides input
damping*
30 Hz filter off (f max )
30 Hzfilter on
The decimal point determines
the way of displsaing the
count values. It does not
affect counting.
0
no decimal place
0.0
one decimal place
0.00 two decimal places
0.000 three decimal places
manual reset via the red
RESET key and electrical
reset via the RESET input
no reset (red RESET key
and RESET input locked)
only electrical reset via the
RESET input
only manual reset via the
red RESET key
The programming routine is
repeated once more. The
values set until now can be
checked and modified.
The programming routine
wil be left and all values set
will be stored as new
parameters.
Afterwards the device is
ready for operation.