PARAMETERS
Edge test
tE.D.
6
0 = off
1 = on
LP.o.
7
Partial opening
Time for automatic closure from partial opening
TP.C.
8
(0=off)
Flashing light output setup
FP.r.
9
0 = Steady
1 = Flashing
tP.r.
10
Pre-flashing time (0 = off)
Courtesy light setup
0 = On at end of operation for time TCY
FC.Y.
11
1 = On if gate not closed + duration of TCY
2 = On if courtesy light timer (TCY) time not out
tC.Y.
12
Courtesy light on time
Hold-to-run
de.a.
13
0 = off
1 = on
0 = deactivated
1 = gate open light ON/OFF
2 = gate open light proportional
- Slow flashing with gate opening
- Quick flashing with gate closing
- Steady light if gate open
- 2 flashes + pause with gate stationary (position
IN.D.
14
other than closed)
3 = Electric lock
4 = Magnetic electric lock function with output active
when gate/door is closed
N.B. interface with an external relay with 24 Vdc
winding. To activate this function, the pre-flash must
be enabled at the recommended value of 1 sec (tP.r.
≠ 0)
Service interval cycle threshold
se.r.
15
(0 = off)
Enabling of continuous flashing indicating service
required with se.r. ≠ 0 (only active with gate closed)
se.f.
16
0 = off
1 = on
EL.T.
17
Electric lock activation time in seconds
Water hammer on opening
HA.o.
18
0 = disabled
Water hammer on closing
HA.c.
19
0 = disabled
Motor release from closed/open limit switch. Useful
for lightweight gates
RE.L.
20
0 = off
1 to 10 release levels (1 = minimum release, 10 =
maximum release)
High-speed motor start-up
ST.P.
21
0 = on
1 = off
Leaf 1 closing delay with gate open
DM.I.
22
0 = Off
1 = 1 to 20 Seconds On
Reset to default values
1= RAY2524/RAY2224
DE.F.
23
2= REVO2224
3= INT24
4= STAR2024
To set the default values: 1) access the advanced programming
function; 2) select the "dEf" parameter"; 3) activate the modification
mode ("0" on display"); 4) accept the modification (press "MENU"
DESCRIPTION
and hold it down). A countdown should now appear: 49,48...,1
down to "don". Release the button when finished.
DEFAULT
MIN
0
0
50
0
0
0
1
0
0
0
0
0
0
0
0
0
0
0
10
0
0
0
2
1
0
0
0
0
0
0
0
0
1
0
1
1
EN
MAX
UNIT
1
100
%
900
s
1
20
s
2
900
s
1
4
x 1000
200
cycles
1
10
s
100
*100ms
100
*100ms
10
1
20
4
31