Compare the measurements with the data given in the table and select the appropriate
pair of adapters.
Alternatively, the pair of connectors can also be selected by an accurate visual
comparison. The pairing of the connecting leads can be identified by the numbers
stamped in them (e.g. 64).
Connect the selected pair of adapters to the vehicle and the control unit (2).
Designation
DPAK 64G
DPAK 65G
DPAK 66G
DPAK 67G
DPAK 68G
DPAK 69G
DPAK 70G

3. Test procedure

Start the engine and allow to idle until the tester control unit has filled completely with
bubble-free fuel.
Read off the pressure or vacuum on the vacuum gauge (1) and compare with the vehicle
manufacturer's data.
4. Removing the tester
Disconnect the tester from the vehicle, catch any fuel which may escape and empty the
tester completely.

5. Technical Data

Compound gauge :
Connecting lead lengths :
Dimensions:
6. Pack specification
1
Tester LR 180_AK 2 with 1 compound gauge
14 Connecting leads (7 pairs)
1
Plastic case
1
Directions for use
Plug diameter (a)
9.89 mm
7.89 mm
7.89 mm
9.49 mm
7.89 mm
9.89 mm
11.8 mm
NG 63, -1 to +9 bar
0.20 m each
145 x 35 x 170 mm (L x W x H)
Length, approx. (b)
30 mm
19.5 mm
30.6 mm
19.5 mm
19.5 mm
22.2 mm
10.8 mm