Direction for use

Analog tester for fuel systems with quick-fit connectors as per SAE standard.
Suitable for petrol and Diesel fuels.

1. Safety instructions

The tester may only
be used by trained
personnel.
Safety precautions:
No naked flames or sources of fire.
Use exhaust gas extraction system.
Trap escaping fuel and dispose of in the technically correct manner.
With the engine running, follow the safety instructions laid down by the vehicle manufacturer.

2. Connection to the vehicle

*
Note:
Only SAE plugs and SAE quick-fit connectors of precisely the same diameter may be
connected to each other. Otherwise, this will lead to leaks and/or it will be impossible
to release the connection.
Connect the vacuum gauge (1) to the control unit (2).
Disconnect the SAE connection to the vehicle.
Measure the diameter and length of the plug to the locking point precisely (!),
see illustrations below.
When working on or with vehicle components, there is a:
Ø = (a)
Fire risk
- 6 -
english
Combustion hazard
L = (b)