INDICATIONS ON THE DISPLAY
Alarm indications
Both travel limits have cut in.
The letter
, will appear on the display and the system remains blocked.
The warning lights will flash for a three second period which is repeated
every six seconds. The only way to solve this problem is to check the travel
limits for obstacles or damage and then restart the system.
Parameters loaded from EEPROM are wrong
The letter
, will flash on the display and the system remains blocked. The
only way to solve this situation is to enter the program mode and reprogram
the system. If the problem persists after reprogramming, the problem regards
the EEPROM (incorrect memorising). Switch off the power to the system,
after a few seconds switch it back on and then reprogram the system.
Time programming mode block
(caused by: TB, FTCI, FTCS )
Function indications
defining the system configuration
waiting period after the parameter programming stage
waiting period after deceleration programming
waiting period after electrical input sensor programming
deceleration time setting (value 1)
level 1 electrical input sensor
work time programming
opening stage
stop
automatic reclosing pause (only if enabled)
closing stage
updating the electrical input monitoring system
battery mode
block caused by a flat battery
MANUAL OPERATION MODE
This can be used to close the gate/door (or open it) under the direct control
of the operator (in this mode the security devices are excluded as well as the
electrical input monitoring system, only the stop button "TB" and the closing
and opening direction photoelectric cells
aim of this command is to make installation easier and to allow you to have
the gate/door completely closed before starting the programming procedure.
In this mode the LED "L3" (marked "UPL") will remain lit.
FCA/FCC
"
"
are operational ). The
• Closing manoeuvre
This is obtained by pressing the button "SEL".
The motor will block in the closing direction due to:
- releasing the "SEL" button (takes you out of the "manual operation
mode").
- activating the stop button "TB": to move the door again you must first release
the "SEL" button and then press it again.
- activating the closing direction travel limit: pressing the "SEL" button will not
cause the door to close but it will switch the courtesy light on.
• Opening manoeuvre
This is obtained by pressing the button "SEL", and then the "PROG" button
straight away.
The motor will block in the opening direction due to:
- releasing both buttons (takes you out of the "manual operation mode").
- activating the stop button "TB": to move the door again you must first release
both buttons and then press them again.
- activating the amperometrical travel limit
• Travel direction inversion
If the door is closing: to enable an opening manoeuvre:
- press the "PROG" button
If the door is opening: to enable a closing manoeuvre:
- release the "PROG" button
• Courtesy light
The courtesy light remains on all the time while in the "manual operation
mode". it also lights up when a SEL/PROG is given but the travel limit blocks
the command.
FUNCTION MODE
) Automatic
Selected by enabling automatic reclosing (programming step "2", number
not flashing). When the door is completely closed the opening command
will start a complete cycle which will end with automatic reclosing and the
courtesy light switching off. Automatic reclosing starts after the programmed
pause period has elapsed when the opening cycle has been completed or
straight away after the intervention of a photoelectric cell (the intervention of
a photoelectric cell causes the pause time to be reset).
During the pause time the symbol
stop button during this period will stop automatic reclosing and consequently
stop the display from flashing. Pressing the "TA" command will reset the pause
time count after which the gate/door will close. If opening is carried out by
keeping the "TA" command continuously activated (time controlled contact)
reclosing will only occur when the contact has been released and the pause
time has elapsed (clock mode).
The intervention of the amperometrical travel limits will block the gate/door.
The indicator light remains lit until the gate/door has completely closed.
Note: The courtesy light switches on automatically each time a movement
command is given either by control button or by radio. The intervention of a
photoelectric cell during reclosing has no effect on the timing of the courtesy
light.
2) Semiautomatic
Selected by disabling automatic reclosing (programming step "2", number
flashing).
Work cycle control using separate opening and closing commands. When the
door has reached the completely open position the system will wait until it
receives a closing command either via an external control button or via radio
control, before completing the cycle.
The activation of one of the amperometrical travel limits cause the gate/door
to stop and the termination of the opening cycle.
The courtesy light will switch off after the set period has elapsed .
The indicator light remains lit until the gate/door is completely closed.
8
will flash on the display and pressing the