On/Off Switch; Input Jack - Peavey PV 2015 D Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 31
Please read this guide carefully to ensure your personal safety as well as the safety of your equipment.
Never break off the ground pin on any equipment. It is provided for your safety. If the outlet used does not have
a ground pin, a suitable grounding adapter should be used and the third wire should be grounded properly. To
prevent the risk of shock or fire hazard, always be sure that the mixer and all other associated equipment are
properly grounded.
FUSE
2a
The unit is AC power line fuse protected from overloads and fault conditions with a slow-blow 5 x 20mm 250V
fuse. This fuse is located within the cap of the fuse enclosure just to the left of the ON-OFF switch. If the fuse
fails, THE FUSE MUST BE REPLACED WITH THE SAME TYPE AND VALUE IN ORDER TO AVOID DAMAGE TO THE
EQUIPMENT AND TO PREVENT VOIDING THE WARRANTY!
The fuse in the PV
For 100-120VAC operation, a fuse rated at 6.3 amps should be used. In the USA, types GDC, GMC, 215, 218, and
477 cartridge-style 5 x 20 mm size fuses with a 6.3 amp 250V rating can be used.
For 220-240VAC operation, a fuse rated at 3.15 amps and 250V should be used, which conforms to the
international fuse classification T3.15AL.
If the unit continues to blow replacement fuses, do not keep replacing them, it should be taken to a qualified
service center for repair.
To replace the fuse, be sure to remove the IEC power cord from the IEC socket (2).
Remove the cap to the fuse enclosure (2a), using a flat-blade screwdriver tip inserted into the fuse cap slot. Push
the cap in and turn the cap counterclockwise and pull the cap out. The blown fuse should come out with the cap.
Remove the blown fuse and replace it with the proper type per instructions previously supplied. Then, once the new
fuse has been put in place, re-insert the fuse enclosure cap, push in and turn the cap clockwise, and make sure it
is fully seated. Before re-attaching the IEC power cord to the IEC socket, make sure the Power switch is in the OFF
position, so that intermittent contact of the IEC cord while it is being connected will not unduly stress the amplifier or
the fuse. Now re-attach the IEC power cord, and you can then use the Power switch to turn the unit on.

ON/OFF SWITCH

3
This rocker switch supplies AC power to the PV 2015D when switched to the ON position.
T O p p a n e l

INPUT JACK

4
The line level-input is of the medium impedance balanced type. Jack (4) is a combination female XLR and 1/4"
TRS connector, and can be supplied with a balanced or unbalanced input signal.
LEVEL
5
Controls the gain (volume) of the Input (4) of the powered speaker system.
®
2015D can be replaced with a time-delay type 5 x 20 mm size 250V rated fuse.