Setting the alarm symbol and changing the channel setting
Standard settings:
Lynx TX-1 is equipped with a transmitter that sends signals wirelessly to the receiver installed in the
Lynx system. The transmitter is located under the blue cover and has an 8-pole microswitch that is used
for two purposes:
• Alarm symbol (fire, telephone, door,
etc). Lynx TX-1 is pre-set for door but
another suitable symbol can be selec-
ted if required. The symbols that can
be selected depend on the receiver that
is being used. If you wish to change
the type of alarm, set switches 6, 7 and
8 on Lynx TX-1 as shown in the table
alongside.
• Channels. There is a total of 16 diffe-
rent channels (0-9, A-F). Transmitters
and receivers in the system must be set
to the same channel so that they can
communicate. Channel 0 is reserved
for a common fire alarm and should
not be used. Lynx TX-1 and all recei-
vers in the Lynx system are all pre-set
to channel 9, and then act together
without alteration.
Changing the channel setting
In some cases, it may be necessary to
change the channel setting. If two or
more users live near one another, the
alarms can interfere. This can be recti-
fied by changing the channel settings so
that they are different for everyone. Any
channel can be selected except Channel
0. If you wish to change channel, set the
switches on Lynx TX-1 as shown in the
table alongside. To change channels on
the receiver, see user manual.
6
Test switch for installation. When it is set to ON, Lynx
TX-1 transmits continuously. This makes it easier to
find the most suitable location for the receiver.
Channel selector switch
Telephone
Door
Fire
Baby
Pager
Optional
Public alert
Channel:
Alarm selector switch
Switch:
6
7
On On Off
On Off On
Off On On
Off Off Off
On Off Off
Off Off On
Off On Off
Switch:
1
2
3
0 Off Off Off Off Off
1 On Off Off Off Off
2 Off On Off Off Off
3 On On Off Off Off
4 Off Off Off On Off
5 On Off Off On Off
6 Off On Off On Off
7 On On Off On Off
8 Off Off Off Off On
9 On Off Off Off On
A Off On Off Off On
B On On Off Off On
C Off Off Off On On
D On Off Off On On
E Off On Off On On
F On On Off On On
Setting the alarm
selector microswitches
8
Setting the
channel selector
4
5
microswitches
Common channel for
fire alarm
Pre-set channel on
Lynx TX-1 and all
receivers