Servicing and Cleaning the Aqua Trol Cell
Turn off power to the Aqua Trol before removing the electrolytic cell. Once removed, look inside
the cell and inspect for scale formation (light colored crusty or flaky deposits) on the plates and for
any debris which has passed through the filter and caught on the plates. If no deposits are visible,
reinstall. If deposits are seen, use a high pressure garden hose and try to flush the scale off. If this
is not successful, use a plastic or wood tool (do not use metal as this will scratch the coating off the
plates) and scrape deposits off of the plates. Note that a buildup on the cell indicates that there is an
unusually high calcium level in the pool (old pool water is usually the cause). If this is not corrected,
you can expect to have to periodically clean the cell. The simplest way to avoid this is to bring the
pool chemistry to the recommended levels as specified.
Mild Acid Washing: Use only in severe cases where flushing and scraping will not remove the
majority of deposits. To acid wash, turn off power to Aqua Trol. Remove cell from piping. In a clean
plastic container, mix a 4:1 solution of water to muriatic acid (one gallon of water to one quart of
muriatic acid). ALWAYS POUR ACID INTO WATER - NEVER POUR WATER INTO ACID. Be sure to wear
rubber gloves and appropriate eye protection. The level of the solution in the container should just
reach the top of the cell so that the wire harness compartment is NOT submerged. It may be helpful
to coil the wiring before immersing the cell. The cell should soak for a few minutes and then rinse
with a high pressure garden hose. If any deposits are still visible, repeat soaking and rinsing. Replace
cell and inspect again periodically.
Winterizing
The Aqua Trol electrolytic cell and flow detection switch will be damaged by freezing water just as
your pool plumbing would. In areas of the country which experience severe or extended periods of
freezing temperatures, be sure to drain all water from the pump, filter, and supply and return lines
before any freezing conditions occur. The electronic control is capable of withstanding any winter
weather and should not be removed.
Spring Start-up
DO NOT turn the Aqua Trol on, until the pool water chemistry has been brought to the proper levels.
This information can be found on page 2.
7