Installation
Installation must be performed in accordance with Local and NEC codes.
Preparing Pool Water
Refer to page 2 for recommended chemical levels. The pool's chemistry must be balanced BEFORE
activating the Aqua Trol. NOTE: If the pool does not have new water, add 1 quart (1 liter) of metal
remover and 1 quart (1 liter) of non-copper based algaecide to the pool, per manufacturers instruc-
tions. This ensures a quick, troublefree transfer to the Aqua Trol system.
Mounting the Aqua Trol Control
The Aqua Trol is contained in a raintight enclosure that is suitable for outdoor mounting. The control
must be mounted a minimum of 5 ft. (2 meters) horizontal distance (or more if local codes require)
from the pool.
The control is designed to mount vertically on a flat surface. Because the enclosure also acts as a
heat sink (disperses heat from inside the box), it is important not to block the four sides of the control.
Do not mount the Aqua Trol in a panel or tight enclosed area.
Aqua Trol
8
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS