Bonding
A lug used for bonding is attached to the bottom of the Aqua Trol enclosure. Connect to the pool
bonding system using minimum 8AWG copper wire if required by code.
Electrolytic Cell
Route the cell cable through the enclosure cutout and connect to the Aqua Trol.
Diagnostic Displays
Sequential pushes of the small "diagnostic" button next to the LCD display will cause the Aqua Trol
to display the following information:
1.
Pool temperature (xx degrees Fahrenheit or Celsius)
2.
Cell voltage (typically 22.0 to 26.0 volts when chlorine is being generated, otherwise 30-35V)
3.
Cell current (typically 2.50 to 4.00 amps when chlorine is being generated, otherwise 0 amps)
4.
Desired Output % ("0P" -- "100P" depending on knob position )
5.
Instant salinity ( -xxxx ppm or -x.xx grams/Liter)
6.
Product name sent to the display ("AL-6" signifies "Aqua Trol" (STD), ("AL-7" signifies "Aqua
Trol Return-Jet")
7.
Software revision level (r1.xx)
On the 8th push of the button the display will revert back to the default salt display. Also, if the button
is not pushed for 30 seconds, the display will revert back to the standard salt display.
Common Problems and Solutions
1.
"Power" LED not on
Check to make sure 120 VAC input power is connected to the Aqua Trol control. Verify input voltage
with a voltmeter. If there is input power, the fuse may have blown. The Aqua Trol is protected by a
20 amp mini ATO fuse located on the circuit board above the cell connector.
10
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
INPUT POWER
120 VAC linecord
to GFCI receptacle/breaker
Troubleshooting
Cutout for
cell cable
Bonding lug to
pool bonding system