Remove Mounting Plate

Depending on your model, the mounting plate may
be in the foam packaging or it may be attached
to the back of the microwave oven.
NOTE: To avoid possible damage to the work surface,
cover the work surface.
1. Remove any remaining contents from the microwave
oven cavity.
2. If the mounting plate is attached to the back of
the microwave oven, remove it and set it aside.
3. Tape the microwave oven door closed so that door does
not swing open while the microwave oven is being handled.
NOTE: To avoid damage to the microwave oven, do not grip
or use the door or door handle while the microwave oven
is being handled.

Rotate Blower Motor

The microwave oven is set for recirculation installation. For wall
or roof venting, changes must be made to the venting system.
NOTE: Skip this section if you are using recirculation installation.
Keep the damper assembly in case the venting method
is changed or the microwave oven is reinstalled in another
location where wall or roof venting may be used.

Wall Venting Installation Only

1. Remove screws attaching damper plate to top of microwave
oven exterior. Slide damper plate toward the front of the
microwave oven and lift up.
A. Screws
B. Damper plate
2. Keep damper plate and screws together and set aside.

INSTALLATION INSTRUCTIONS

A
B
3. Remove 2 screws attaching blower motor to back
of microwave oven.
A
A. Screws (in recessed holes)
4. Lift blower motor out of microwave oven.
A. Blower motor
5. Rotate blower motor 180° so that exhaust ports face
the back of microwave oven, and then lower blower motor
back into the microwave oven.
A. Exhaust port
A
A