Installation Guide
Installation in a baseboard heater
ELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect AC power
before beginning installation.
Wiring must comply with local electrical codes. Use special CO/ALR
solderless connectors if supply wires are made of aluminum.
Disconnect the heater wires from the supply wires. If the heater has a built-in thermostat,
remove it.
1 Remove the knockout on the side of the heater.
3 Clean the back panel inside the wiring
compartment where the relay will be installed.
Peel the adhesive backing off the relay and stick
the relay on the back panel.
5 Insert the antenna plug into the relay receptacle
until you hear a click.
69-2472EF—03
Relay wires must be at the top
2 Remove the locknut from the antenna and peel
off the adhesive backing. Feed the antenna cable
through the knockout and install the antenna ver-
tically as shown. Put the locknut on and tighten.
N L : For 120V application
L2 L1 : For 240V application
4 Connect the heater wires and the supply wires to
the relay.
See page 6 if you are connecting more than
one heater.
Install plug if
applicable.
6 Put the heater cover back. (If a built-in
thermostat was removed, install one of the
supplied plugs to cover the hole on the existing
cover.) Apply power to the heater. Do not install
the antenna cover yet.
ELECTRICAL HAZARD
Can cause electrical shock. Install heater
cover plate before applying power.
4