Installation Guide
Anti-freeze
When this function is on, the EIM will maintain the room temperature at 13°C (55°F) if
it loses communication with the thermostat or if the thermostat sensor is defective.
Leave the protection on unless the EIM is installed in a junction box in a separate room
from the heater.
To turn off the Anti-freeze protection, proceed as follows:
#
Display
1
2
System test
1 From the Home screen, press
ambient temperature by at least 2°. Press Temporaire (temporary).
2 Wait for Chauffe (heat) to display on the thermostat.
3 Verify if the heater becomes hot.
4 Press Annuler (cancel) to return the thermostat to its previous mode.
69-2472EF—03
Button
until the setpoint temperature is above the room
18
Step
From the installer's setup
menu, press
as needed
to select Hors-Gel (anti-
freeze) and press OK.
Press
or
to set to Non
(no). Press OK.