Power spectrum of DCS 500 Converters
DCS 501 non-regenerative Converters (2-Q)
Continuous
at supply Voltage [V AC]
Armature
Current
400
500
600
I
[A]
DC
25
50
75
100
125
180
225
245
315
405
470
610
740
900
900
1200
1500
2000
1900
2050
2500
3000
2050
2600
3300
4000
4800
5200
DCS 502 regenerative Converters (4-Q)
Continuous
at supply Voltage [V AC]
Armature
Current
400
500
600
I
[A]
DC
25
50
75
100
110
140
200
250
270
350
450
520
680
820
1000
900
1200
1500
2000
1900
2050
2500
3000
2050
2600
3300
4000
4800
5200
I 4
690
790
1000
C1
C2
C2b
A5
A6
A7
690
790
1000
C1
C2
C2b
A5
A6
A7
3ADW000177R0200_DCS500B_QuickGuide_edisf_b
Technical Data of DCS 500 Converters
Converter Ratings
Rated supply voltage: 230 to 1000 V AC ±10%, 3-ph
Rated frequency:
50 Hz or 60 Hz
Dyn. frequency range: 50 Hz: ±5 Hz; 60 Hz: ± 5 Hz
DC current range:
25...5200 A DC
Operating Conditions:
Ambient temperature: 0 to +40°C (32...104°F)
Storage temperature: -40 to +55°C (-40...130°F)
Relative humidity:
5 to 95%,
Degree of protection: IP 00
Dimensions
mm
h
w
d
h
420
273
195
16.54 10.75
469
273
228
18.46 10.75
505
273
361
19.88 10.75 14.21
652
273
384
25.66 10.75 15.11
1050 510
410
41.34 20.07 16.14
1750 460
410
68.90 18.11 16.14
1750 760
570
68.90 29.92 22.44
Field supply
• up to 16 A incorporated in the
drive module (not for A6 and
A7-converters)
• 25...520 A external
I/O- connections
• 8 Digital Inputs
• 8 Digital Outputs
• 4 Analogue Inputs
• 3 Analogue Outputs
• 1 Tachogenerator input
• 1 Encoder input
• ±10 V Ref. voltage
• Multiple fieldbus adapters
avail.
CDP 312 Panel
Removable control and display
panel with plain text display for:
• Reference and feedback display
• Drive control
• Parameter programming
• Fault detection
• Parameter upload and download
• Lockable operation
CMT
PC-based commissioning tool for:
• Online Start-up
• Diagnosis
• Maintenance
• Troubleshooting
• Programming
DCS 500 converters are available
as modules or in cabinets as DCA
500 Enclosed converters.
no condensation
Module
frame
inches
kg
w
d
C1 (25...75 A)
7.67
8
C1 (100...140A)
8.97
12
C2
29
C2b
42
A5
110
A6
180
A7
315
Protection
• Speed feedback error
• Overtemperature
• Overload
• Overspeed
• Zero speed
• Armature overcurrent
• Armature ripple
• Armature overvoltage
• Minimum field current
• Field overcurrent
• Motor stalled
• Mains over- and undervoltage
• Auxiliary undervoltage
• Incorrect mains phase sequence
Tools
GAD
PC-based application tool
for:
• Drawing
• Creating Software func-
tions
• Documentation
Serial Communication
• Profibus
• CS 31
• ModBus
• ModBus+
• CANopen
• ControlNet
• DeviceNet
taken from/for further information:
DCS500B Flyer
3ADW000151
size

Publicité

Table des Matières
loading