Product Details - CDVI BO800RN Manuel D'installation

Bandeaux architecturaux et poignées ventouses
Masquer les pouces Voir aussi pour BO800RN:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION MANUAL
BO800RN - BO1200RN - PBO400RN - PBO800RN
Retrofi t housing and retrofi t handles

Product Details

Description
Number of 400Kg
magnets
Lock section
with cover
Architectural handle
with fi xing cover
End caps for handle
End caps
for lock section
RAL colour (option)
Finishes
Description
Number of 400Kg magnets
Lock section
with cover
Architectural handle
with fi xing cover
End caps for handle
End caps for
lock section
RAL colour
(option)
Cut-to-length service
provided (optional)
Magnets & armatures supplied
non-mounted (specify)
2] INFORMATION & RECOMMANDATIONS
Information
The electromagnets are pre-fi tted within the lock
section. The armature plates are pre-fi tted within
the architectural handle. Both sections are supplied
with end caps.
Power Considerations
The handle is designed to house electromagnets
with a holding force of 400Kg each. These units
can be supplied by either 12Vdc or 24Vdc depending
upon your preferred choice. The current required
depends on the amount of electromagnetic locks,
and the voltage chosen – please see Technical
Specifi cation, and ensure you have allocated
suffi cient power to correct performance.
For example, the BO800RN2.5m (2.5m housing with
2 magnetic locks) would require: PSU12/2
BO800RN
BO1200RN
2,5 m
2,5 m
Retrofi t housing
Retrofi t housing
(2,5 m)
(2,5 m)
2
3
1
1
1
1
2
2
2
2
Standard
(Ref. Product)
(Ref. Product)
AL
Anodised
Anodised
aluminium (SAA)
champagne
-
BO800RN
BO1200RN
PBO800RN
3 m
3 m
Retrofi t
Retrofi t housing
Retrofi t handle
housing
(3 m)
2
3
1
1
1
1
2
2
2
2
(Ref. Product)
CH
BL
RAL Black
-
-
-
-
or ARD2/12 at 12Vdc PSU24/1 or ARD24 at 24Vdc.
General Advice
The 2 parts of the architectural housing are designed
to be surface mounted on the door and frame,
where they should be parallel when the door is
closed. If there is a rebate, then it will be necessary
to pack out the lower part to be parallel to the other.
Wiring
Plan your 9/10 cable routes before commencing
installation. We recommend a maximum
distance of 10m from the power supply
to the electromagnetic locks (to prevent volt drop).
If the distance is greater, then make sure you have
increased the cross section of the cable
to compensate.
PBO400RN
60 cm
40 cm
Retrofi t handle
(600 mm)
(400 mm)
2
1
1
1
1
1
2
2
2
2
(Ref. Product)
(Ref. Product)
WH
RAL White
Untreated
-
cdvi.com
cdvigroup.com
EN
Housing
-
-
-
-
-
BT
-
-
3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bo1200rnPbo800rnPbo400rn

Table des Matières