ENGLISH
 Press the ENTER button to confirm: the display shows "CONFIRM?"
 Use DOWN and UP buttons to select YES / NO
 Press the ENTER button to confirm.
 SAVE was selected: the current settings of the setup menu are saved to memory.
 LOAD was selected: the previously saved settings are loaded.
ETHERNET IP ADDRESS
Used to set the IP address of the projector while controlled via the Ethernet ports.
 Press the MODE button until the desired function is showing on the display.
 Press the ENTER button: the values can be changed
 Use DOWN and UP buttons to select the desired values for the IP-address.
 Once the correct IP-address shows on the display, press the ENTER button to save it.
ETHERNET NET MASK
Used to set the Net Mask of the projector while controlled via the Ethernet ports.
 Press the MODE button until the desired function is showing on the display.
 Press the ENTER button: the values can be changed
 Use DOWN and UP buttons to select the desired net mask, there are 3 options:
 255.000.000.000
 255.255.000.000
 255.255.255.000
 Once the correct option shows on the display, press the ENTER button to save it.
DMX UNIVERSE
Used to set which DMX-universe should be used while controlled via the Ethernet ports.
 Press the MODE button until the desired function is showing on the display.
 Press the ENTER button: the values can be changed
 Use DOWN and UP buttons to select the desired DMX-universe from 000 to 255.
 Once the correct universe shows on the display, press the ENTER button to save it.
Remark: the 512 DMX-channels of the selected DMX-universe are available on the DMX-output.
ETHERNET PROTOCOL
Used to select which Ethernet protocol you want to use for communication.
 Press the MODE button until the desired function is showing on the display.
 Press the ENTER button: the values can be changed
 Use DOWN and UP buttons to select the desired Ethernet protocol.
 Once the correct option shows on the display, press the ENTER button to save it.
Remark: currently only the Art-Net protocol is supported. Other protocols will follow, see firmware updates.
FIRMWARE VERSION
Used to show the current version of the firmware.
 Press the MODE button until the FIRMWARE is showing on the display.
The firmware of this unit can be upgraded using a special upgrade tool with Windows® software. (separately