Always use hearing protection!
The declared vibration value, which has been measured by a standardized test method, can be used to
compare different tools with each other and for a preliminary assessment of exposure.
WARNING! The actual vibration level when using power tools may differ from the specified maximum value,
depending on how the tool is used. It is therefore necessary to determine which safety precautions are
required to protect the user, based on an estimate of exposure in actual operating conditions (taking into
account all stages of the work cycle, e.g. the time when the tool is switched off and when it is idling, in
addition to the start-up time).
Power source
This tool is designed to operate on clean, dry, compressed air at regulated pressures between 70 and 120
PSI. The system should include a filter, a pressure regulator and automatic lubricator located as close as
possible to the tool (within 4.5 metres is ideal). All compressed air contains moisture and other contaminates
that are detrimental to internal components of the tool. An air filter will remove most of these contaminates
and significantly prolong the life of the tool. If a lubricator is not installed, place five or six drops of oil into
the tool's air inlet at the start of each workday.
IMPORTANT! All line components (hoses, connectors, filters, regulators, etc.) must have a minimum
working pressure rating of 150 PSI (10.3 bar) or 150% of the maximum system pressure, whichever is
greater.
Do not connect this tool to a system with maximum pressure greater than 180 PSI (12.3 bar).
Remove all pressure from the tool by disconnecting the quick coupling from the connector on the rear of
the tool.
Disconnect the tool from the air supply before carrying out any maintenance on the tool, removing a jammed
nail, leaving the work area, moving the tool or handing it over to someone else.
Preparing the tool before driving
13.
Read the Operating Instructions before connecting the tool to the air supply.
IMPORTANT!
•
Never point the tool at your body or at anyone else.
•
Always connect the tool to the air supply before loading fasteners.
•
Do not load nails with the trigger or safety mechanism held in.
Always wear Z87 approved safety glasses and ear protection when preparing and using the tool.
•
Never use a tool that is leaking air or needs repairing.
•
TECHNICAL DATA
Min. operating air pressure
Max. operating air pressure
Air intake
Strip nails with diameters
Nail length
Nail capacity, 21° collation angle
Sound power level, LwA
Sound pressure level, LpA
Vibration level
Weight
OPERATION
ENGLISH
4.9 kg/
cm²
8.4 kg/
cm²
1/4
"
2.87-3.33 mm
55-90 mm
60
113,8 dB(A), K= 1,5 dB
100,8 dB(A), K= 1,5 dB
3,24 m/s2, K= 1,5 m/s2
3.6 kg
20