TTI TSX Serie Manuel D'instructions page 10

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Once the required value is entered press the CONFIRM key and the set current will be updated
immediately. To exit without making any changes press the ESCAPE key. If a mistake is made
during entry press the AMPS key and start again.
The maximum and minimum values accepted will depend on the particular model, see the
specification section for details.
Set OVP
The Over-Voltage Protection (OVP) value is not shown in the main display; however, it is active
and if at any time the actual value of the output voltage exceeds the set value the OVP circuit will
immediately shut down the output, thus avoiding any damage to the circuit under test. The OVP
circuit will protect against adjustments by the user or the GPIB or RS232, external voltages
impressed across the output terminals, or a failure in the circuitry of the instrument itself. If the
OVP circuit trips for any reason the main displays will both show
shut down, i.e. switched off. The system will then attempt to recover from the trip and if
successful the
To set the OVP press the OVP key. The status display will show the set OVP value and the OVP
LED will light. A new value may now be entered from the numeric keypad. The value will be in
VOLTS and the POINT key may be used to enter decimal digits. Once the required value is
entered press the CONFIRM key and the set OVP will be updated immediately. To exit without
making any changes press the ESCAPE key. If a mistake is made during entry press the OVP
key and start again.
The maximum and minimum values accepted will depend on the particular model, see the
specification section for details.
Delta Volts
Delta Volts mode is entered by pressing the DeltaV key. The status display will show the set Delta
Volts value and the DeltaV LED will light. A new value may now be entered from the numeric
keypad. The value will be in Volts and the POINT key may be used to enter decimal digits. Once
the required value is entered press the CONFIRM key and the set Delta Volts value will be
updated immediately. To exit without making any changes press the ESCAPE key. If a mistake is
made during entry press the DeltaV key and start again.
While in DeltaV mode, i.e. while the DeltaV LED is on, the UP and DOWN keys are active and will
increment or decrement the set volts value by the set DeltaV value shown in the status display.
The VOLTS LED next to the knob will also be on indicating that the knob is active for adjusting
volts. Turning the knob will increment or decrement the set volts value in 10mV steps irrespective
of the set DeltaV value.
The maximum value for DeltaV is 1·00V. The minimum value is 0·00V.
Delta Amps
Delta Amps mode is entered by pressing the Deltal key. The status display will show the set Delta
Amps value and the Deltal LED will light. A new value may now be entered from the numeric
keypad. The value will be in Amps and the POINT key may be used to enter decimal digits. Once
the required value is entered press the CONFIRM key and the set Delta Amps value will be
updated immediately. To exit without making any changes press the ESCAPE key. If a mistake is
made during entry press the Deltal key and start again.
Whilst in Delta Amps mode, i.e. while the Deltal LED is on, the UP and DOWN keys are active
and will increment or decrement the set current value by the set Delta Amps value shown in the
status display. The AMPS LED next to the knob will also be on indicating that the knob is active
for adjusting current. Turning the knob will increment or decrement the set current value in 10mA
steps irrespective of the set Delta Amps value.
The maximum value for Delta Amps is 1·00A. The minimum value is 0·00A.
triP
message will be removed and normal operation will resume.
triP
and the output will be
9

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Tsx3510pTsx1820p

Table des Matières