installation instructions
building in
hole
locating
pin
hole
pin
GB 18
Place the pan supports and the burner caps on
the cooking appliance. Attention! Place the
pan supports straight down to prevent
scratching of the drip tray.
Pay attention to the position of the pan
supports. The pan supports should have their
narrow edges next to each other.
Connect to the electricity supply.
Check that the appliance works.
appliance variant I, natural gas
burner
diameter
rating
25 mbar
mm
simmer: high setting
0.67-0.85
0.36
simmer: low setting
semi rapid: high setting
1.00 / 1.25
0.45
semi rapid: low setting
rapid: high setting
1.30
0.53
rapid: low setting
1.60
2-ring burner: high setting
A=0 mm
0.90
2-ring burner: low setting
appliance variant II, liquid gas low pressure
burner
diameter
rating
29 mbar
I 3 + I 3B/P
mm
kW / gr/h
simmer: high setting
0.45
0.80 / 58
0.26
0.30 / 22
simmer: low setting
semi rapid: high setting
0.65
1.70 / 122
0.30
0.38 / 27
semi rapid: low setting
rapid: high setting
0.80
2.80 / 202
0.36
0.55 / 40
rapid: low setting
0.98
4.35 / 310
2-ring burner: high setting
A=4.0 mm
0.80
2.20 / 155
2-ring burner: low setting
installation instructions
building in
diameter
diameter
rating
G25
G20
20 mbar
I 2L
I 2H I 2E I 2E +
I 2ELL
mm
kW
mm
kW
0.67-0.85
0.90
0.67-0.85
0.95
0.36
0.22
0.36
0.23
1.00 / 1.25
2.00
1.00 / 1.25
2.20
0.45
0.33
0.45
0.36
1.30
2.90
1.30
3.20
0.53
0.49
0.53
0.55
1.70
4.35
1.53
4.35
A=0 mm
A=0 mm
1.00
1.15
0.90
1.25
rating
rating
G30
G31
G31
29 mbar
37 mbar
I 3P
I 3P
kW / gr/h
kW / gr/h
0.70 / 50
0.80 / 58
0.26 / 19
0.30 / 22
1.50 / 108
1.70 / 122
0.33 / 24
0.38 / 27
2.40 / 173
2.80 / 202
0.48 / 35
0.55 / 40
3.70 / 270
4.35 / 310
1.90 / 140
2.20 / 155
A
A
rating
G25
20 mbar
I 2ELL
kW
0.80
0.20
1.80
0.30
2.60
0.44
4.35
1.25
GB 19