5 Preventative Maintenance
5.1 Cleaning
Clean the equipment with a damp cloth only and avoid excessive moisture around any electrical sockets. If required you may use a mild
detergent, however do not use abrasives or solvents as they may damage the warning labels on the equipment.
5.2 Maintenance Schedule
Description Of Service Required
Component
Operation
Generator
Check the status indicators located on the front panel.
System
Check the inlet air quality.
Generator
Check for air leaks
Generator
Check the pressure gauges during purging for excessive back pressure.
Generator
Check the condition of the electrical supply cables and conduits.
Generator
Check oxygen sensor(s) and calibrate if necessary
Generator
Check for cyclic operation
Replace Exhaust silencer and filter element(s)
Filtration
Recommended Service A
Replace Oxygen sensor(s)
Generator
Recommended Service B
Replace control valves
Generator
Recommended Service C
Replace cylinder and solenoid valves
Generator
Recommended Service D
1. The service operations should be performed at the hours run or fixed time intervals specified (whichever occurs first)
Key:
Check
(Operator)
24 - EN
Essential Procedure
(Service Personnel only)
Service Recommended Every:
Essential Procedure
(Responsible Body or Service Personnel only)
1