Install The Sprocket Cover; Installation - Craftsman 139.18489DS Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ASSEMBLY STEP 6

Install the Sprocket Cover

1. Position the sprocket cover over the garage door opener
sprocket and attach with hex screws.
You have now fi nished assembling your garage door opener.
Please read the following warnings before proceeding to the
installation section.

INSTALLATION

IMPORTANT INSTALLATION INSTRUCTIONS
To reduce the risk of SEVERE INJURY or DEATH:
1. READ AND FOLLOW ALL INSTALLATION WARNINGS AND
INSTRUCTIONS.
2. Install garage door opener ONLY on properly balanced and
lubricated garage door. An improperly balanced door may
NOT reverse when required and could result in SEVERE
INJURY or DEATH.
3. ALL repairs to cables, spring assemblies and other
hardware MUST be made by a trained door systems
technician BEFORE installing opener.
4. Disable ALL locks and remove ALL ropes connected to
garage door BEFORE installing opener to avoid
entanglement.
5. Install garage door opener 7 feet (2.13 m) or more above
floor.
6. Mount emergency release within reach, but at least 6 feet
(1.83 m) above the floor and avoiding contact with
vehicles to avoid accidental release.
7. NEVER connect garage door opener to power source until
instructed to do so.
To avoid possible SERIOUS INJURY to fingers from moving
garage door opener:
• ALWAYS keep hand clear of sprocket while operating
opener.
• Securely attach sprocket cover BEFORE operating.
g
Sprocket Cover
WARNING
WARNING
8. NEVER wear watches, rings or loose clothing while
installing or servicing opener. They could be caught in
garage door or opener mechanisms.
9. Install wall-mounted garage door control:
• within sight of the garage door.
• out of reach of children at minimum height of
5 feet (1.5 m).
• away from ALL moving parts of the door.
10. Place entrapment warning label on wall next to garage
door control.
11. Place manual release/safety reverse test label in plain view
on inside of garage door.
12. Upon completion of installation, test safety reversal
system. Door MUST reverse on contact with a 1-1/2"
(3.8 cm) high object (or a 2x4 laid flat) on the floor.
11
Hex Screws
#8x3/8"
Sprocket
Mounting
Plate

Publicité

Chapitres

Table des Matières
loading