Problem
Bad electrical connection.
Tripped electrical circuit breaker/fuse.
Pump obstructed.
Pump fails to start or restart
No water flow.
Control unit not installed vertically in proper orientation.
Minimum flow of 0.15 gpm not sustained.
Pump works intermittently
Plumbing or check valve leak
System flow continues above 0.15 gpm.
Device contains debris preventing switch closure.
Pump will not shut off
Control unit not installed vertically in proper orientation.
Plumbing or check valve leak

DIMENSIONS

130 mm (5.1")
190 mm (7.5")
66 mm (2.6")
185 mm (7.3")
251 mm (9.9")
Probable Causes
SWC
81.2 mm (3.2")
140 mm (5.5")
SWP
60 mm (2.4")
Troubleshooting
Check the electrical connections.
Check electrical circuit breaker panel.
Check pump and suction line for debris.
Check plumbing and water supply.
Correct installation so that the control device is vertical, with all writing on
the product label in the proper upright position.
Increase water use.
Repair or replace faulty plumbing/check valve
Confirm that there is no water demand.
Check plumbing system for leak.
Clear debris from unit or plumbing.
Correct installation so that the control device is vertical, with all writing on
the product label in the proper upright position.
Repair or replace faulty plumbing/check valve
156 mm (6.1")
216 mm (8.5")
Corrective Action
150.5 mm (5.9")