Install Range Hood; Connect Vent System - Whirlpool WVI75UC6DS Instructions D'installation Et Guide D'utilisation Et D'entretien

Hotte de cuisinière configurèe en îlot 36''
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5. Using 2 or more people, lift the range hood assembly under
the structure.
A. Lower vertical supports
B. Range hood assembly
6. Attach the range hood assembly to the lower vertical
supports with 2 leveling screws and 2 nuts.
D
A. 2 - Leveling screws
B. Lower vertical support
A
B
C
C. Place leveling screws
through the structure
D. Nut
7. Install the 4 vertical supports with 16 - 4.2x8 mm screws.
Make sure all screws are securely tightened.
A
B
A. 4 - Lower vertical
supports
B. 16 - 4.2x8 mm screws

Install Range Hood

Non-Vented (recirculating) Installation
1. Attach the air deflector to the upper horizontal support
using 4 mounting screws.
B
A
A. Deflector
B. Mounting screws
2. Measure the length of 6" (15.2 cm) duct needed
to connect the transition to the deflector.
NOTE: Vent should fit up inside the deflector
1" (2.5 cm) minimum.
3. Install vent between the transition and the deflector.
NOTE: To make vent installation easier, temporarily remove
the deflector from the chimney support bracket and replace
after vent section is in place.
4. Seal all connections with vent clamps.

Connect Vent System

1. Install vent system.
2. Push duct over the exhaust outlet. Seal all connections
with vent clamps.
3. Use caulk to seal all openings.
B