TECHNICAL DATA
NATURAL GAS FLOW RATE
L.P.G. FLOW RATE
HEATING CAPACITY
L.P.G. PRESSURE
NOx EMISSIONS
MOTOR
ELECTRIC FEEDING
ABSORBED ELECTRICAL POWER *
IGNITION TRANSFORMER
EQUIPMENT
WEIGHT
OPERATION
*) Total absorption upon start-up with ignition transformer on
STANDARD ACCESSORIES
SEAL
INSULATING ROPE
STUD BOLTS
NUTS
FLAT WASHERS
OPERATING RANGE
- Note: The operating ranges have been obtained in compliance with Standard EN 676
MIN
m
n/h
3
MAX
m
n/h
3
MIN
m
n/h
3
MAX
m
n/h
3
MIN
kW
MAX
kW
mbar
mg/kWh
< 120
r.p.m.
)
Kg
0006080876_201403
BTG 15
BTG 20
5.0
6.0
16.1
20.6
1.9
2.3
6.25
8.0
50
160
205
< 80
(class II EN 676)
(class III EN 676)
185 W - 2800 - 230V-50Hz
1N ~ 230 V ±10% - 50 Hz
0.33 kW
26 kV 40 mA - 230V - 50Hz
LANDIS LME 21
ON/OFF
BTG 15
BTG 20
No. 1
No. 1
No. 4 - M10 x 50
No. 4 - M10
No. 4 - Ø10
6 / 24
BTG 28
10
28.2
3.9
10.9
60
100
280
30
< 120
(class II EN 676)
17
BTG 28