GUTMANN Fonda Mode D'emploi page 26

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 82
EN
Activated carbon filter
For activated carbon filters fitted in GUTMANN extractor hoods (C Version), please read
the separate operating instructions provided!
Transport, unpacking, installation
Condensation may occur if the appliance is brought
into the installation site from a cold environment.
Please wait until the appliance has adjusted to the
temperature and is completely dry before operating
it. The acclimatization period depends on the temperature difference and the type and
design of the appliance. However, it should be at least 12 hours.
Connecting the power supply
Check that the rated voltage of the device corresponds to the local mains voltage. Incor-
rect setting will damage or destroy the device.The device may only be installed on the
electrical mains by a trained electrician who is familiar with and carefully observes the
local regulations and additional regulations of the local electrical supply companies. The
protection against accidental contact of operationally insulated parts must be ensured
after assembly. It must be possible to disconnect the device from the mains at all poles by
means of disconnecting devices. When switched off, there must be a contact distance of
3 mm between the contacts. Suitable isolating devices are LS switches, fuses and contac-
tors.
Attention! Make sure that the wires are inserted correctly and that the screws are
tightened tightly.We are not responsible for incidents caused by incorrect connection, or
missing or incorrect earth connection.Check before operation whether all cables and
wires are faultless and undamaged. In particular, make sure that the cables have no
kinks, have not been laid too short around corners and that there are no objects on the
cables. Furthermore, make sure that all plug connections are tight. Faulty shielding or
wiring endangers your health (electric shock) and can destroy other equipment. Devices
with a mains plug are equipped with a safety-tested mains cable from the country of use
and must only be connected to a properly earthed earth contact socket, otherwise there
is a risk of electric shock. Make sure that the socket at the device or the earth contact
socket of the house installation is freely accessible so that the mains cable can be dis-
connected from the socket in an emergency or during service or maintenance work.
If the power supply cable of this appliance is damaged, it must be replaced by the manu-
facturer, its customer services or a similarly qualified person in order to avoid hazards.
The appliance must not be operated with an external timer or an external telecontrol
system. The reliable and safe operation of the hob is only guaranteed if it is connected to
the public electricity network.
The hob must not be connected to a stand-alone inverter that is used with an auto-
nomous power supply, such as solar power. Otherwise a safety switch-off may occur
when switching on the hob due to voltage spikes. The electronics may be damaged.
The electrical safety of the hob is only guaranteed when it is connected to an earth
conductor system installed according to the regulations. This basic safety
requirement must exist.
26

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

2800 ml

Table des Matières