WARNING
FOR YOUR SAFETY
• Do NOT attempt to operate
heater until you have
read and understand all
precautions in Section 1
"Safety First." Failure to
do so can result in serious
personal injury, death, or
property damage.
• If at any time you are unable
to light burner and smell
gas, wait 5 minutes to allow
gas to dissipate before
attempting to light heater.
• Do NOT touch emitter or
dome or move heater for at
least 45 minutes after use.
LOW
LOW
HIGH
HIGH
LOW
LOW
HIGH
HIGH
13
®

Operation

Caution: Do NOT attempt to operate heater until you have read and
understand all precautions in section 1 "Safety First."

Before Turning Gas Supply ON

Before Lighting

View Hole

Lighting

Note: This heater is equipped with a Pilot Light that allows for safer
startups and shutdowns. Pilot must be lit before Main Burner can be
started.
Pilot
Pilot
(Push in)
OFF
OFF
Pilot
Pilot
(Push in)
OFF
OFF
Contact 1-800-762-1142 for assistance.
Do not return to place of purchase.
Your heater was designed and approved for OUTDOOR USE ONLY. DO
NOT use it inside a building, garage, or any other enclosed area.
Make sure surrounding areas are free of combustible materials, gasoline,
and other flammable vapors or liquids.
Ensure that there is no obstruction to air ventilation.
Be sure all gas connections are tight and there are no leaks.
Be sure the access panel is clear of debris.
Be sure any component removed during assembly or servicing is
replaced and fastened prior to starting.
Heater should be thoroughly inspected before each use, and by a
qualified service person at least annually.
If relighting a hot heater, always wait at least 5 minutes.
Inspect the hose assembly for evidence of excessive abrasion, cuts, or
wear. Suspected areas should be leak tested. If the hose leaks, it must
be replaced prior to operation. Only use the replacement hose assembly
specified by manufacturer.
Push Control Knob IN and turn to OFF.
Wait 5 minutes for any gas to clear.
Open Viewing Hole by sliding cover to either side.
Push Control Knob IN and rotate to Pilot position.
Note: For initial start or after re-connecting gas source, hold Control
Knob IN for 2 minutes to purge air from gas lines before proceeding.
Push Igniter button once. Pilot Light flame will appear and be visible
through Viewing Hole.
Release Control Knob after 30 seconds. Pilot Light will remain lit. If not,
return to first bullet point.
Turn Control Knob to ON. Main Burner will light immediately. Flame is
visible through Viewing Hole. If not, return to first bullet point.
If you experience any ignition problem consult "Troubleshooting" on
page 16.
Owner's manual: model 233010 outdoor patio heater