DIAGNOSTIC CYCLE CHART

It is recommended to take note of, then clear the Fault History before running the Diagnostic Cycle.
NOTE: The basket must be empty during this test. Some loads will not be available on all models.
Step
Washer Function
Warm water fills through the
1
Detergent valve
Hot water fills through the
2
Detergent
valve
Cold water fills through the
3
Detergent
valve
4
Drain pump turns on
5
Lid locks
6
Shift to Wash
7
Wash
8
Shift to Spin
9
Spin up to 500 RPM then stop
10
Unlock lid
Total test time in minutes is expected to be between 4-7 minutes.
Steps 1-3 will display Sense LED. Step 4 will display Soak LED. Steps 5-7 will display Wash LED. Steps 8-10 will display Done LED.
16
FOR SERVICE TECHNICIAN'S USE ONLY

Recommended Procedure

If no water, use Water Valve test sequence to manually turn on and test the hot and
cold water valves.
If no water, use Water Valve test sequence to manually turn on and test the valve.
If no water, use Water valve test sequence to manually turn on and test the valve.
If water is not draining, use Drain Pump test sequence to manually turn on and test
the drain pump.
Lid must be closed. If lid does not lock, use Wash test sequence to manually test
the lid lock.
Use Wash test sequence to manually test the shifter.
Use Wash test sequence to manually test the motor operation in both direction.
Use Spin test sequence to manually test the shifter.
Use Spin test sequence to manually test the motor.
If lid does not unlock, use service Water valve test sequence to manually test the
lid lock.
Estimated Time
(seconds)
60
5
5
15
5
30
5
30
200
5
DO NOT REMOVE OR DESTROY