Removing the Water Inlet Valve

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
NOTE: The water inlet valve is replaced as an assembly, which includes all
four valves, bracket, and valve assembly harness.
1. Unplug washer or disconnect power.
2. Turn off the water supply to the washer.
3. Disconnect hot and cold inlet water hoses.
4. Complete the steps
1-8
from section Removing the Console.
5. Disconnect the Water Inlet Valve connector from the ACU (connector
varies depending on model, features, and control board).
6. Using a 1/4" nut driver, remove the two (2) hex-head screws (one on
each side) securing the water inlet valve to the Top Panel of the washer.
DO NOT REMOVE OR DESTROY
FOR SERVICE TECHNICIAN'S USE ONLY

Removing the Main Control

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
NOTE: ACU may vary depending on model number and features.
1. Unplug washer or disconnect power.
2. Turn off the water supply to the washer.
3. Complete the steps
1-8
from section Removing the Console.
4. Remove pressure hose from ACU.
5. Disconnect all connectors from the ACU.
A
A. ACU Screw
6. Using a 1/4" nut driver, remove the hex-head screw securing the ACU to
the Top Panel of the washer as shown in above figure. Slide ACU to the
left and lift to remove.
B
B
B
B
B. ACU Connectors