Anest Iwata DDP 70 B.TE Manuel D'instruction Et De Maintenance page 14

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

EN
DPS-70 C - DPS-70 CN DIAPHRAGM PUMPS
8. USE
This section describes the diaphragm pump use in compliance with the safety standards in force.
Read this section carefully.
8.1 SAFETY RULES DURING USE
• TO USE the diaphragm pump COMPLY WITH the safety precautions and rules described below.
• The manufacturing company declines all responsibility if the operator does not comply with them.
It is not to be held responsible for any carelessness during the pump use, either.
• If the system is used improperly, it could be broken by causing serious damage.
• Do not change the system; use only ANEST IWATA original spare parts.
• Check the system daily: repair or replace immediately all worn or damaged parts.
• Never exceed the maximum working pressure: 7 bar (100 psi)
• IT IS FORBIDDEN to use the equipment for purposes that are different from the ones it is destined to which are described
in the use and maintenance manual. If in doubt, apply to your ANEST IWATA reseller.
• Use paints and solvents compatible with the system parts they come in touch with.
• Refer to the paint and solvent features mentioned by the manufacturer.
• Wear the protective clothes described in section 8.2.
• Comply with all the local standards on electric safety and fire risks.
8.2 SAFETY CLOTHES
Wear some protective gloves and goggles, an oxygen mask
and some ear protections during working.
In any case, follow the references of the current regulations.
8.3 PREWASH
1. Make sure the pump is installed correctly (see section 7.4).
2. Soak the suction tube into the washing liquid, or fill the hopper or the tank according to the model used.
3. Put the ball valve in the right position.
4. Adjust the inlet pressure between 2.0 and 7 bar.
5. Open gradually the two-way valve for paint recirculation (B on page 15). The washing liquid will have to circulate through
the dip tube recirculation pipe.
-
If the Tank mount model is used, the washing liquid will circulate through the reciculation pipe.
-
In the Hopper model, recirculation pipe is directly connected to the hopper.
6. Close the two-way valve for paint recirculation and adjust the paint pressure by means of Paint Regulator
(Recommended pressure for washing 3.0 bar)
7. Press the gun trigger (or supply the automatic gun opening control with some air), without spraying air and let the
washing fluid circulate for some minutes.
8. Make sure the washing has been done and then discharge the pump residual liquid and stop it.
WARNING
THE PUMP MUST BE WASHED BEFORE USING IT FOR THE FIRST TIME, IF IT IS NOT USED FOR A LONG TIME AND
AFTER ANY COLOUR CHANGE.
8.4 STARTING
BEFORE BEGINNING WORKING, START THE PUMP BY FOLLOWING THE INSTRUCTIONS BELOW:
1. Connect ground wire set to ground.
2. For all models with suction pipe, dip it into the product tank to be pumped.
For the model with hopper, fill it with the product to be pumped.
For the model on tank, fill the product tank to be pumped.
14

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Ddp 70 bn.teDps 70 c.teDps70 cn.te

Table des Matières