3
2
30.23
LAMP ON
1
AMONT
ON
OFF
MAINS
FUSE
TELECOMMANDE /
REMOTE CONTROL
HMI 1200
220/240V 50Hz
OPERATION
THE POWER
SUPPLY UNIT (PSU)
1 Mains checklight.
2 "ON-OFF" switch.
3 Lamp ON,
checklight.
4 Fuse
(Checklight 3 o ).
HEAD
(Checklight 3 on).
HEAD
robert juliat
32, rue de Beaumont F 60530 Fresnoy-en-Thelle phone: +33 (0)3.44.26.51.89 - fax: +33 (0)3.44.26.90.79 - www.robertjuliat.com
1200W
SYMPTOMS
Checklight 1 does
not light up when the
power supply unit is
connected.
No light coming
The checklight 3 does
through the
not light up when 1
lamp house.
is on.
Hard striking on.
The lamp doesn't light
up.
No light coming through the lamp house.
(lamp house lit).
No light in the lens tube.
Bad quality light beam.
No ventilation from the lamp house.
WARNING : Do not use the lighting unit if the fan is not working.
Premature deterioration of the lter
TECHNICAL FILE
FOLLOWSPOTS
TROUBLE SHOOTING.
POSSIBLE CAUSES
No power.
The switch is OFF.
Circuit breaker and
transformer are OFF.
Check the Spark-gap.
Fuse blown out.
Bad contact. Harting plug
power supply / Head.
Side trapdoors are not
closed.
Lamp is badly mounted.
Ignition failure.
(igniter, Spark-gap).
Colour changer unit
closed.
Iris cassette closed.
Mirrors and lenses not
in right condition or
not in place.
fan is not working.
(Note: The fan doesn't work until the lamp and checklight 3 are ON.)
- No HT* gel inserted.
- Infra-Red lter not engaged.
(*) Place the darker colours in front. HT = High temperature resistance
LUCY / SK /
FLO / VICTOR
Section B - 3
3
2
1
1800W
4
SOLUTIONS
Check the mains and
cable connections +
electrical diagram,
refer to pages A - 5 & C - 23.
Repeat the operation,
refer to page A - 7.
Turn ON the circuit
breakers, refer to page A - 7.
Refer to page B - 1.
Change the fuse 5 .
Refer to page A - 5
Check the connections,
refer to page A - 5.
Make sure the doors are
properly closed. Adjust the
position of the mini-circuit
breaker.
Refer to page A - 7.
Refer to page B - 1.
Open colour unit at the
front of the lighting unit.
Check iris blades are open
when turning the handle.
Refer to page B - 1.
Refer to page A - 5.
- Insert HT* gel.
- Engage Infra-Red lter.

Publicité