dial the number of seconds you want the door
lock to stay ON (3 digits from 000 to 120);
press Pn; you hear a confirmation tone and the
red LEDs go back ON without flashing;
continue by entering the code of a new pro-
gramming or exit the programming mode by
moving the jumper J1 to position 1-2.
System programming (code 121)
This programming is used to activate or
deactivate the functions listed in table 2.
To make the programming you must:
enter the programming mode following the
instructions described in " Entering the
programming mode ";
enter code 121 and press Pn; you hear the
confirmation tone and the red LEDs flash once
every second to indicate that you are program-
ming mode 1;
a - press "P1" to activate/deactivate mode 1; a
low tone indicates deactivation, and a high
tone indicates activation;
b - press "Pn" to confirm and go to the next
programming; you hear a confirmation tone
and the red LEDs generate a series of flashings
to indicate the number of the next mode; if you
do not need to change one or more operation
modes, press "Pn" to go to the next modes;
repeat actions a and b to programme all modes
2, 3 and 4;
after programming and confirming mode 5
with "Pn", press "Pn" three more times to exit
the system programming mode; you hear a
confirmation tone and the red LEDs go back
on without flashing.
Note . The programming is not saved until all
operation modes are confirmed.
continue by entering the code of a new pro-
gramming or exit the programming mode by
moving the jumper J1 to position 1-2.
Programming the buttons with camera
deactivation during the call (code 210)
This programming is used to set the buttons for
which the camera must not be activated upon
pressing. To make the programming you must:
enter the programming mode following the
instructions described in " Entering the
programming mode ";
enter code 210 and press Pn; you hear a
confirmation tone and the red LEDs start flash-
ing;
press, one at a time, all the buttons for which
the camera must not be activated upon press-
ing;
exit the programming mode moving the jumper
J1 to position 1-2.
Table 2 - System programming (code 121)
Operation modes
mode 1
activate conversation upon call
mode 2
tone activation
mode 3
video switch-on activation (*)
mode 4
presence of second camera
mode 5
activation / management of buttons
with camera deactivation
mode 6
reserved;
leave deactivated
mode 7
reserved;
leave deactivated
mode 8
reserved;
leave deactivated
(*) If the installation is only intercom system (without the presence of videointercoms) the function
must be disables.
Resetting the buttons with camera
deactivation during the call (code 211)
To reset the camera activation function during
the call for the buttons for which this function was
deactivated with the previous programming
operation ( code 210 ), you must:
enter the programming mode following the
instructions described in " Entering the
programming mode ";
enter code 211 and press Pn; you hear a
confirmation tone and the red LEDs start flash-
ing;
press, one at a time, the buttons for which you
want to restore the camera activation function
during the call; you hear a confirmation tone;
exit the programming mode moving the jumper
J1 to position 1-2.
Managing the Special Buttons ( code 233 )
You can change the address that has been
automatically assigned during the programming
of the external door stations (see codes 112 and
113 ) for a maximum number of 20 buttons. This
function is useful if you want to change the
progressive sequence of some calls and/or if you
want to activate actuators for special functions.
To make the programming you must:
enter the programming mode following the
instructions described in " Entering the
programming mode ";
enter code 233 and press Pn; you hear a
confirmation tone and the red LEDs start flash-
ing;
a -
dial the address of the extension (codes
from 001 to 200) or the address actuator (codes
from 211 to 220) following the instructions
contained in " entering codes or addresses ";
b -
keep pressed the button to which you want
to assign the address that has been entered
previously until you hear the confirmation tone;
repeat operations a and b to programme other
buttons or exit moving the jumper J1 to position
1-2.
Resetting Special Buttons ( code 233 )
To reset one or more special buttons with the
address that has been automatically assigned
during the programming of the external door
stations ( see codes 112 and 113 ), you must:
enter the programming mode following the
instructions described in " Entering the
programming mode ";
enter code 233 and press Pn; you hear a
confirmation tone and the red LEDs start flash-
ing;
a – keep pressed the button you want to reset
until you hear the confirmation tone;
Default
Press button "P1"
settings
high tone
enabled
enabled
enabled
enabled
enabled
enabled
disabled
enabled
disabled
enabled
disabled
-
disabled
-
disabled
-
repeat operation a to reset other buttons or exit
moving the jumper J1 to position 1-2.
Resetting default settings
After you have entered the programming mode
as described in the corresponding chapter, you
must:
dial 000 following the instructions contained in
" entering codes or addresses ";
press Pn; you hear a confirmation tone and the
red LEDs start flashing;
dial 123 following the instructions contained in
" entering codes or addresses ";
press Pn; you hear a confirmation tone and the
white LEDs of the camera start flashing;
exit the programming mode moving the jumper
J1 from 2-3 to position 1-2.
Warning. After you have carried out this
procedure all programming settings will be reset
to the default values.
To make the programming easier and to
remind your self the stored addresses,
please fill in the following table
Codes Addresses
111
low tone
disabled
112
disabled
113
disabled
disabled
114
disabled
121
disabled
disabled
disabled
Values from.. to..
231 ÷ 250
001 ÷ 200
001 ÷ 200
000 ÷ 120
see table 2
Mi 2424