INSTALLATION & PREPARATION
NOZZLE REVIEW:
Various nozzles may be quick-connected into the end of the wand to
change the spray pattern or use the detergent feature. When using Quick
Connects (Q.C.), be certain the connection is securely locked. If not, the
high pressure water may shoot the nozzle from the wand, causing severe
injury or serious damage. To determine spray fan, refer to the actual num-
ber stamped on the nozzle. The first two digits indicate the spray fan in
degrees, i.e.; 15=15°, 25=25°, 65=detergent/low pressure.
1. The 15° nozzle (YELLOW): This is a chiseling nozzle. The spray should
be directed at a 45° angle to the surface and used like a scraper to remove
paint, grease and dirt. Uses: Surface preparation (removing mildew stains
and paint chips).
2. The 25° nozzle (GREEN): This is a flushing nozzle. This pattern is best
suited for flushing dirt, mud, and grime. Uses: Wet sweeping leaves from
walks, curbs and driveways, cleaning stable floors, washing swimming
pool bottoms, degreasing engines.
3. The 65° nozzle (BLACK): This is a low pressure detergent application
nozzle. This broad spray pattern distributes solution over vast areas under
low pressure. Uses: Detergent application, misting or rinsing.
NOZZLE CONNECTION:
1. Be certain the trigger gun is locked in the "OFF" position. See WARNING,
right.
2. The nozzle assembly should be disconnected from the gun/wand assembly
at this time by retracting the locking ring on the quick-connect fitting to
remove the nozzle.
WP-Cold Water Direct Driven Operator's Manual
QUICK-CONNECT FITTING
WARNING RISK OF INJECTION
CAUSING SEVERE INJURY!
NEVER LOOK DIRECTLY AT THE
NOZZLE ORIFICE UNLESS IT IS
DISCONNECTED FROM THE
GUN/WAND ASSEMBLY!
CONNECTION OF Q.C. NOZZLES
QUICK-CONNECT (Q.C.)
WARNING RISK OF SEVERE
INJURY!
THE TRIGGER GUN SHOULD
ALWAYS BE LOCKED IN THE
OFF POSITION WHEN NOT IN
USE!
11