6. Remove the
grease filters
by pulling
down the
metal latch
tab and
tilting filters
downward to
remove.
7. Attach non-duct collar to non-duct plenum using
(4) no. 8 x 3/8" pan head screws.
8. Measure
distance "A".
NON-DUCT PLENUM
This will be the
length of the
NON-DUCT COLLAR
extended flex
6" ALUMINUM
duct.
FLEX DUCT
9. Attach
aluminum
flexible duct to
DUCT CONNECTOR
(without flaps)
the damper /
duct connector
with a tie wrap.
10. Attach flexible
duct to non-duct
plenum collar
and secure with
tie wrap. Tape
all joints with
duct tape.
NOTE: 10-ft. ceilings require 10-ft. Flue Extension Model
FXN58SS (purchase separately). Discard the upper flue
supplied with your hood and replace it with the Model
FXN58SS flue extension.
LOWER FLUE MOUNTING BRACKET
LOWER
FLUE
11. Remove the upper flue from inside the lower flue. Install
the lower flue bracket to the lower flue using (2) flue
bracket screws (no. 8 x 3/8"). Make sure that the bracket is
positioned inside of the lower flue flanges - with the slots on
top. Carefully replace the upper flue inside the lower flue.
Remove protective plastic film covering the lower flue only.
12. Carefully place both flues into the recessed area of hood
top. Slightly push aside the upper flue to avoid any damage
while installing the lower flue to the hood top by using
(2) no. 8 x 3/8" screws through the lower flue side slots.
13. Attach non-duct plenum with collar to upper flue using
(4) no. 8 x 3/8" pan head screws.
14. Hold hood up close to wall mounting location and plug
power cord into wall outlet.
15. Align the hood and center it above the hood mounting bracket.
Gently lower the hood until it securely engages the bracket.
SIDE VIEW
3-5/8"
A
16. With the hood hanging in place, drill through both holes
located in the inside lower back of hood using a 5/16" drill
bit. Insert the included drywall anchors into the drilled holes
(one for each hole). Install (2) washers and (2) no. 8 x 1½"
mounting screws through the back of the hood and into
the drywall anchors. Verify that the hood is centered and
leveled. Tighten all screws completely.
17. Attach (2)
two non-duct
recirculation
filters to sides
of blower by
aligning key lock
slot and rotating
until filters lock
into place.
For replacement non-duct recirculation filters - purchase
S97018030 or ROUNDFILTER.
18. Reinstall grease filters by aligning rear filter tabs with
slots in the hood. Pull down the metal latch tab, push filter
into position and release. Make sure filters are securely
engaged after installation.
UPPER
FLUE
19. Slide up the upper flue upward until it is aligned with its
upper flue mounting bracket. The bracket should be inside
the flue. Secure the upper flue to the upper flue mounting
bracket using (2) no. 8 x 3/8" mounting screws.
20. Remove protective plastic film covering the flue and the hood.
MODELS BW5030SSL • BW5036SSL
INSIDE BACK OF HOOD
MOTOR/BLOWER
ASSEMBLY
HOLES LOCATION
UPPER FLUE MOUNTING BRACKET