6 Complete the working steps described in Section & "Generating the Pressure" on
Page 15 .
4.2 Connecting and Venting the Test Object
1 Turn the pressure release valve counterclockwise to open the pressure release valve.
2 Press the hand grips together 10 times to vent the valve channels.
3 Turn the pressure release valve clockwise until the pressure release valve is firmly
closed.
4 Screw one pressure hose connection to the hand pump and tighten it.
5 Select an appropriate adapter and seal for the test object.
6 Screw the adapter to the test hose and tighten it.
7 Mount the seal on the test object connection and screw the test object 2 revolutions
in the appropriate adapter, but do not tighten it yet.
8 Press the hand grips together as often as necessary until the hydraulic fluid escapes
at the test object connection.
Ä The pressure hose and test object connection are vented.
9 Screw the test object tight at its maximum torque of 25 Nm.
V2.0/07/20
Starting the Test Kit
13