Led Operation And Fault Display - Delta SOLiViA 3.3 Manuel D'utilisation Et D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 117
6.11

LED operation and fault display

Three light-emitting diodes (LEDs), which display the operational state of the solar inverter, are at-
tached on the front:
LED STATUS
green: <off>
red: <off>
yellow: <off>
green: <on>
red: <on>
yellow: <on>
green: <flashes>
red: <off>
yellow: <off>
green: <on>
red: <off>
yellow: <off>
green: <off>
red: <on/off>
yellow: <on/off>
green: <off>
red: <on/off>
yellow: <on>
green: <on/off>
red: <on/off>
yellow: <flashes>
18
Operation
Earth Fault (B)
Failure
OPERATIONAL STATE
Night disconnection.
Initialization.
Input- and grid moni-
toring.
Feed-in operation.
Equipment fault.
General error
condition.
Warning message.
• LED (A), green: „Operation" displays the
operational state.
(A)
• LED (B), red: „Earth Fault" displays an insula-
tion resistance fault or PV grounding (GND)
fault on the DC side.
(C)
• LED (C), yellow: „Failure" displays existing
faults internally or externally and whether the
grid feed-in operation has been interrupted.
EXPLANATION
The input voltage (UPV) is lower than 100 V.
The solar inverter is not feeding power to the grid.
Input voltages:
UPV: 100 V to 150 V
(self test ongoing).
Starting conditions are tested.
Normal operational state:
UPV: 150 V to 450 V.
Internal or external fault
(interrupted feed).
See also display messages!
Solar inverter is not connected to the grid.
No power is delivered.
See also display messages!
You can carry on using the solar inverter.
See also display messages!
Operation and installation manual SOLIVIA 3.3 EU G3

Publicité

Table des Matières
loading

Table des Matières