TECHNICAL CHARACTERISTICS 
 
Frequency 
Coding 
Memory 
Events 
Number of relays 
Anti‐panic function 
Alarm function 
Power supply 
Relay contacts 
Standby / op. consumption 
Battery 
Access control output (Max. 2 readers without external 
power supply) 
Op. temperature 
Watertightness 
Size 
Box dimensions 
 
INSTALLATION AND CONNECTIONS 
Attach the rear part of the housing to the wall using the plugs and screws supplied. Pass the cables 
through the bottom of the unit. Connect the power cables to the terminals marked in the mother 
board, as indicated. Fix the unit front to the rear part using the screws supplied. 
 
OPERATION 
The lights on the screen blink to indicate correct power supply to the equipment. 
On  receiving  a  code  the  equipment  checks  if  it  is  in  the  memory,  activating  the  programmes 
relay(s). 
If the equipment code is not stored in the memory, the equipment will not perform any action, and 
the message "no" will be displayed on the screen. 
 
MENUS 
To  access  the  menu,  press  any  key  and  enter  the  password  using  the 
number, 
 changes digit, C confirms password. If the password is incorrect, the message "Err" is 
displayed on screen and the equipment emits a bleep. 
The manufacturer set password is written on a sticker located on the memory card. 
The menus that will be displayed are: Mod1 (basic mode), Mod2 (advanced mode), ‐‐‐‐ (exit). 
 are used to change mode. To confirm each option, press the C key. 
 
Menu scrolling key 
 
Menu scrolling key 
 
Menu accessing or option validating key 
 
If no action is performed, the equipment exits the program automatically after a period of 60 
seconds and emits two short beeps. 
 
 
DISPLAY 
DESCRIPTION 
Mod1 
Basic mode: Allows programming in multi‐channel mode and individual cancellations. 
Mod2 
Advanced mode: Allows complete management of the unit: programming (F.1), 
cancellations (F.2), time configuration (F.3) and relay configuration(F.4). 
CCA‐200 
868,35MHz 
High security rolling code 
500 codes 
1000 event card (optional) 
1 (expandable to 4) 
Configurable on relay 4 
Only available on proximity equipment 
with alarm function 
230Vac ±10% 
1A 
23mA / 42mA 
CR 2032 3Vdc 
BUS‐L 
‐20ºC to +85ºC 
IP54 (with glands IP65) 
115x95x35mm 
140x220x55mm 
6
keys. 
  increases 