Setting The Presets; Setting Via Decade Keys; Setting With Teach-In Function; Setting The Tracking Presets (Trail) - Kübler CODIX 924 Mode D'emploi

Masquer les pouces Voir aussi pour CODIX 924:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Preset 2 and subsequently with
negative direction and when
count < Preset 2
SUB mode output operations:
timed signal at Output 2,
becomes passive with negative
direction and when count < zero
and subsequently with positive
direction and when count > zero
Duration of timed signal of
Output 1, programmable from
00.01 to 99.99 s.
Timed output is post-triggered.
Active:
Relay or optocoupler are
activated when the preset value
is reached.
Passive:
Relay becomes de-energized or
the optocoupler disabled when
the preset value is reached.
7.9

Setting the presets

7.9.1 Setting via Decade Keys

In programming mode Preset 2 will always be
displayed in the lower line. This is except for the
output operations AddBat, SubBat,AddTot and
SubTot.
Press the Prog/Mode key until
the preset to be changed is
displayed -
Press any decade key
Display switches to the editor mode
Set the desired preset value
using the decade keys
Press the Prog/Mode key to
confirm the value and save it
Display switches to the editor mode of the
next preset
Approx. 3 s after the last press of
the decade keys or by pressing
the Reset key the new preset
value will be accepted and the
counter will switch back to
operating mode.
www.kuebler.com
or
.
or

7.9.2 Setting with Teach-In Function

Program the MPI input to tEAch
In programming mode, select the
preset to be changed using the
Prog/Mode key
Briefly activate the MPI (NPN or PNP input logic)
The current count value will be adopted as
the new preset value
The preset value can subsequently be
further modified via the decade keypad.

7.9.3 Setting the tracking presets (trail)

If a tracking preset has been programmed, the
value for Preset 2 can be set either via the decade
keypad or via the Teach-IN function.
However the value for Preset 1 must be entered via
the decade keypad. In this instance, it is not
possible to use the Teach-In function.
7.10

Set Function

Both the pulse counter and the timer can be set to
a default value by means of the Set function.
Programme the MPI input to SEt
Set menu item SEtPt to the
desired value
Briefly activate the MPI (NPN or PNP input logic)
For add. output operations the pulse
counter or timer will be set to the SEtPt
default value
For sub. output operations the pulse
counter or timer will be set to the amount
of the value of Preset 2 and the value of
SEtPt .
8

Error message

Err 1
Set value is outside the permitted range
Page 17

Publicité

Table des Matières
loading

Table des Matières