DeFelsko PosiTest CMM Mode D'emploi page 4

Masquer les pouces Voir aussi pour PosiTest CMM:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Press to select the desired measurement scale:
n
Concrete 0 to 6%: Used for measuring on
concrete slabs. This scale is calibrated using the
gravimetric method (percentage of dry weight).
Scale
Carbide Method 0 to 4%: Used for measuring on
concrete slabs. This scale is equivalent to the
Carbide method.
Relative 0 to 100: Used for taking readings for
reference comparisons. This scale does not
indicate moisture content or humidity.
Press to toggle between the 3 operating modes:
n
Continuous Measurement Mode (no icon): The
Meter continuously updates the display with the
current measurement value (this is the default
Hold Max
operating mode).
display only when the current measurement is
Hold Max Mode
greater than what is already displayed. Press the
Memory button to record the displayed
measurement into memory and reset the display.
Press the power button to reset the display without
recording the measurement.
updates the display only when the current
Hold Max & Save Mode
measurement is greater than what is already
displayed. Once stabilized, the measurement will
automatically be stored in memory.
NOTE:
Hold Max & Save Mode is
ideal for quickly measuring and
recording measurements on a large
surface especially when used with the
optional Telescopic Extender
(CMMEXT).
Telescopic Extender:
Ergonomically measure
concrete slabs without the
need to bend or kneel.
: The Meter updates the
: The Meter
3

Publicité

Table des Matières
loading

Table des Matières