Technical Specifications; Schematic Diagram - cecotec FORCECLIMA 7050 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 30
ENGLISH
Big Noise.
Compressor
does not work.
The remote
control does
not work.
Displays 'E1'.
Displays 'E2'.
NOTE: If problems not listed in the table occur or recommended solutions do not work, please
contact the professional service organization.

7. TECHNICAL SPECIFICATIONS

Model: ForceClima 7050
Product reference: 05244
Cooling input power: 792 W
Voltage and frequency: 220-240 V, 50 Hz
Cooling capacity: 7000 BTU/h | 1800 Frig/h | 2.06 kW
Refrigerant: R290/130 g
Operating pressure | Suction: 0.6 MP | Discharge: 1.8 MPa
Maximum pressure: 3.0 MPa
Air flow: 300 m
/h
3
Made in China | Designed in Spain

SCHEMATIC DIAGRAM

To see all the technical and specific parameters, please refer to product nameplate.
Due to continuous improvement, we reserve the right to change some design without any
notice.
28
FORCECLIMA 7050
05244_FORCECLIMA 7000_Manual_LI_MV.indd 28
The local air conditioner is not
placed on a flat surface.
Overheat protection starts.
The distance between the
machine and the remote control
is too far.
The remote control is not aligned
with the direction of the remote
control receiver.
Batteries are dead.
The room temperature sensor does
not operate properly.
The pipe temperature sensor do not
operate properly.
Put the local air conditioner on a flat and hard
place (to reduce noise).
Wait for 3 minutes until the temperature is
lowered, and then restart the machine.
Operate the remote control closer to the local
air conditioner, and make sure that the remote
control directly faces to the direction of the
remote control receiver.
Replace batteries.
Check the room temperature sensor and
related circuits.
Check the pipe temperature sensor and
related circuits.
19/12/18 12:51

Publicité

Table des Matières
loading

Table des Matières