Malfunction
Water escapes from the
chuck during operation.
The drilling system has too
much play.
8.2 The diamond core drilling machine is not in working order
Malfunction
The service indicator shows
nothing.
Temperature, overvoltage or
undervoltage indicator is lit.
Temperature, overvoltage
or undervoltage indicator is
flashing.
18
English
Printed: 18.10.2017 | Doc-Nr: PUB / 5236054 / 000 / 02
Possible cause
The diamond core bit isn't securely
tightened in the chuck.
The core bit connection end /
chuck is dirty.
The chuck seal or connection end
is defective.
The diamond core bit isn't securely
tightened in the chuck.
The core bit connection end /
chuck is defective.
The connection between the dia-
mond core drilling machine and the
carriage or spacers is loose.
The carriage has too much play.
Screws / bolts on the drill stand are
loose.
The drill stand is inadequately fas-
tened.
Possible cause
The PRCD isn't switched on.
Interruption in the electric supply.
The motor has overheated.
Fault in the power supply.
Action to be taken
▶ Tighten the diamond core bit
securely.
▶ Remove the core bit. Rotate the
diamond core bit approx. 90°
about its own axis. Refit the
diamond core bit.
▶ Clean and grease the connec-
tion end and/or the chuck.
▶ Check the seal and replace it if
necessary.
▶ Tighten the diamond core bit
securely.
▶ Remove the core bit. Rotate the
diamond core bit approx. 90°
about its own axis. Refit the
diamond core bit.
▶ Check the connection end and
chuck and replace them if
necessary.
▶ Check the connection and,
if necessary, refasten the
diamond core drilling machine.
▶ Adjust the play between the rail
and carriage. → page 16
▶ Check the security of screws
/ bolts on the drill stand and
tighten them if necessary.
▶ Fasten the drill stand more
securely.
Action to be taken
▶ Check that the PRCD is
functioning and switch it on.
▶ Plug in another electric tool or
appliance and check whether it
works.
▶ Check the plug connections,
supply cord, power supply line
and main supply fuse.
▶ Switch the diamond core drilling
machine off (press off-switch in
the middle) and back on again.
Check the water supply. After
cooling down, the diamond core
drilling machine is ready for use
again.
▶ Switch the diamond core drilling
machine off (press off-switch
in the middle) and back on
again. Check the power supply
(especially during operation by
generator or transformer).